- Homegear Reference >
- Devices >
- EnOcean >
- HG-2CH-EO
HG-2CH-EO
Channel 0
Device Configuration Parameters
DEVICE_TYPE
Type: | Enumeration |
---|---|
Default Value: | 0 |
LOCAL_CONTROL
Type: | Enumeration |
---|---|
Default Value: | 0 |
PING_INTERVAL
Type: | Integer |
---|---|
Minimum Value: | 0 |
Maximum Value: | 86400 |
Default Value: | 180 |
RESENDS_WHEN_NO_ACK
Type: | Integer |
---|---|
Minimum Value: | 0 |
Maximum Value: | 20 |
Default Value: | 20 |
RESEND_TIMEOUT
Type: | Integer |
---|---|
Minimum Value: | 0 |
Maximum Value: | 10000 |
Default Value: | 300 |
STEP_TIME
Type: | Integer |
---|---|
Unit: | 100 ms |
Minimum Value: | 0 |
Maximum Value: | 100 |
Default Value: | 0 |
Variables
RF_CHANNEL
Type: | Integer |
---|---|
Readable: | Yes |
Writeable: | No |
Minimum Value: | -1 |
Maximum Value: | 127 |
Default Value: | -1 |
RSSI_DEVICE
Type: | Integer |
---|---|
Readable: | Yes |
Writeable: | No |
STICKY_UNREACH
Type: | Boolean |
---|---|
Readable: | Yes |
Writeable: | Yes |
UNREACH
Type: | Boolean |
---|---|
Readable: | Yes |
Writeable: | No |
Channel 1
Variables
CLOSE
Type: | Action |
---|---|
Readable: | No |
Writeable: | Yes |
END_POSITION
Type: | Enumeration | ||||||||
---|---|---|---|---|---|---|---|---|---|
Readable: | Yes | ||||||||
Writeable: | No | ||||||||
Default Value: | 0 | ||||||||
Values: |
|
LEVEL
Type: | Integer |
---|---|
Readable: | Yes |
Writeable: | Yes |
Minimum Value: | 0 |
Maximum Value: | 100 |
Default Value: | 0 |
OPEN
Type: | Action |
---|---|
Readable: | No |
Writeable: | Yes |
RUNTIME_DOWN
Type: | Integer |
---|---|
Readable: | No |
Writeable: | Yes |
Minimum Value: | 1 |
Maximum Value: | 254 |
Default Value: | 255 |
RUNTIME_UP
Type: | Integer |
---|---|
Readable: | No |
Writeable: | Yes |
Minimum Value: | 1 |
Maximum Value: | 254 |
Default Value: | 255 |
SLATS_REVERSAL_TIME
Type: | Integer |
---|---|
Readable: | No |
Writeable: | Yes |
Minimum Value: | 1 |
Maximum Value: | 254 |
Default Value: | 255 |
STATUS
Type: | Enumeration | ||||||||
---|---|---|---|---|---|---|---|---|---|
Readable: | Yes | ||||||||
Writeable: | No | ||||||||
Default Value: | 0 | ||||||||
Values: |
|
STEP_DOWN
Type: | Action |
---|---|
Readable: | No |
Writeable: | Yes |
STEP_TIME
Type: | Integer |
---|---|
Readable: | Yes |
Writeable: | Yes |
Minimum Value: | 5 |
Maximum Value: | 100 |
Default Value: | 0 |
STEP_UP
Type: | Action |
---|---|
Readable: | No |
Writeable: | Yes |
STOP
Type: | Action |
---|---|
Readable: | No |
Writeable: | Yes |