HM-Sec-Win

 

Channel 0

Device Configuration Parameters

KEYPRESS_SIGNAL

Type:Boolean
Default Value:true

POLLING

Type:Boolean
Default Value:false

POLLING_INTERVAL

Type:Integer
Unit:min
Minimum Value:360
Maximum Value:1440
Default Value:360

ROAMING

Type:Boolean
Default Value:false

SIGNAL

Type:Boolean
Default Value:true

SIGNAL_TONE

Type:Enumeration
Default Value:0

Variables

AES_KEY

Type:Integer
Readable:Yes
Writeable:No
Minimum Value:0
Maximum Value:127

CENTRAL_ADDRESS_SPOOFED

Type:Enumeration
Readable:Yes
Writeable:Yes
Default Value:0
Values:
0UNSET
1CENTRAL_ADDRESS_SPOOFED

CONFIG_PENDING

Type:Boolean
Readable:Yes
Writeable:No

DUTYCYCLE

Type:Boolean
Readable:Yes
Writeable:No

LOWBAT

Type:Boolean
Readable:Yes
Writeable:No

RSSI_DEVICE

Type:Integer
Readable:Yes
Writeable:No

RSSI_PEER

Type:Integer
Readable:Yes
Writeable:No

STICKY_UNREACH

Type:Boolean
Readable:Yes
Writeable:Yes

UNREACH

Type:Boolean
Readable:Yes
Writeable:No

Channel 1

This channel can be the link target for the following link types:

  • WINMATIC

Device Configuration Parameters

AES_ACTIVE

Type:Boolean
Default Value:false

MOUNT_SIDE

Type:Enumeration

PULL_FORCE

Type:Float
Unit:100%
Minimum Value:0
Maximum Value:1
Default Value:0,3

PUSH_FORCE

Type:Float
Unit:100%
Minimum Value:0
Maximum Value:1
Default Value:0,3

TILT_MAX

Type:Integer
Minimum Value:0
Maximum Value:255
Default Value:0

Link Configuration Parameters

LONG_COND_VALUE_HI

Type:Integer
Minimum Value:0
Maximum Value:255
Default Value:0

LONG_COND_VALUE_LO

Type:Integer
Minimum Value:0
Maximum Value:255
Default Value:0

LONG_CT_OFF

Type:Enumeration
Default Value:0

LONG_CT_ON

Type:Enumeration
Default Value:0

LONG_CT_RAMPOFF

Type:Enumeration
Default Value:0

LONG_CT_RAMPON

Type:Enumeration
Default Value:0

LONG_JT_OFF

Type:Enumeration
Default Value:2

LONG_JT_ON

Type:Enumeration
Default Value:5

LONG_JT_RAMPOFF

Type:Enumeration
Default Value:0

LONG_JT_RAMPON

Type:Enumeration
Default Value:0

LONG_OFF_LEVEL

Type:Float
Unit:100%
Minimum Value:0
Maximum Value:1
Default Value:-0,01

LONG_OFF_TIME

Type:Float
Unit:s
Minimum Value:0
Maximum Value:65535
Default Value:111600

LONG_ON_LEVEL

Type:Float
Unit:100%
Minimum Value:0
Maximum Value:1
Default Value:1

LONG_ON_TIME

Type:Float
Unit:s
Minimum Value:0
Maximum Value:65535
Default Value:111600

LONG_RAMPOFF_SPEED

Type:Float
Minimum Value:0
Maximum Value:1
Default Value:0,5

LONG_RAMPON_SPEED

Type:Float
Minimum Value:0
Maximum Value:1
Default Value:0,5

SHORT_COND_VALUE_HI

Type:Integer
Minimum Value:0
Maximum Value:255
Default Value:0

SHORT_COND_VALUE_LO

Type:Integer
Minimum Value:0
Maximum Value:255
Default Value:0

SHORT_CT_OFF

Type:Enumeration
Default Value:0

SHORT_CT_ON

Type:Enumeration
Default Value:0

SHORT_CT_RAMPOFF

Type:Enumeration
Default Value:0

SHORT_CT_RAMPON

Type:Enumeration
Default Value:0

SHORT_JT_OFF

Type:Enumeration
Default Value:2

SHORT_JT_ON

Type:Enumeration
Default Value:5

SHORT_JT_RAMPOFF

Type:Enumeration
Default Value:0

SHORT_JT_RAMPON

Type:Enumeration
Default Value:0

SHORT_OFF_LEVEL

Type:Float
Unit:100%
Minimum Value:0
Maximum Value:1
Default Value:-0,01

SHORT_OFF_TIME

Type:Float
Unit:s
Minimum Value:0
Maximum Value:65535
Default Value:111600

SHORT_ON_LEVEL

Type:Float
Unit:100%
Minimum Value:0
Maximum Value:1
Default Value:1

SHORT_ON_TIME

Type:Float
Unit:s
Minimum Value:0
Maximum Value:65535
Default Value:111600

SHORT_RAMPOFF_SPEED

Type:Float
Minimum Value:0
Maximum Value:1
Default Value:0,5

SHORT_RAMPON_SPEED

Type:Float
Minimum Value:0
Maximum Value:1
Default Value:0,5

UI_HINT

Type:String
Default Value:

Variables

DIRECTION

Type:Enumeration
Readable:Yes
Writeable:No
Default Value:0
Values:
0NONE
1UP
2DOWN
3UNDEFINED

ERROR

Type:Enumeration
Readable:Yes
Writeable:No
Default Value:0
Values:
0NO_ERROR
1MOTOR_TURN_ERROR
2MOTOR_TILT_ERROR

INHIBIT

Type:Boolean
Readable:Yes
Writeable:Yes

LEVEL

Type:Float
Unit:100%
Readable:Yes
Writeable:Yes
Minimum Value:0
Maximum Value:1
Default Value:0

RELOCK_DELAY

Type:Float
Unit:s
Readable:No
Writeable:Yes
Minimum Value:0
Maximum Value:65535
Default Value:111600

SPEED

Type:Float
Unit:100%
Readable:No
Writeable:Yes
Minimum Value:0
Maximum Value:1
Default Value:0,5

STATE_UNCERTAIN

Type:Boolean
Readable:Yes
Writeable:No
Default Value:true

STOP

Type:Action
Readable:No
Writeable:Yes

WORKING

Type:Boolean
Readable:Yes
Writeable:No
Default Value:false

Channel 2

Device Configuration Parameters

AES_ACTIVE

Type:Boolean
Default Value:false

Variables

LEVEL

Type:Float
Unit:100%
Readable:Yes
Writeable:No
Minimum Value:0
Maximum Value:1
Default Value:0

STATUS

Type:Enumeration
Readable:Yes
Writeable:No
Default Value:0
Values:
0TRICKLE_CHARGE
1CHARGE
2DISCHARGE
3STATE_UNKNOWN