HM-ES-TX-WM

 

Channel 0

Device Configuration Parameters

LOCAL_RESET_DISABLE

Type:Boolean
Default Value:false

ROAMING

Type:Boolean
Default Value:false

Variables

AES_KEY

Type:Integer
Readable:Yes
Writeable:No
Minimum Value:0
Maximum Value:127

CENTRAL_ADDRESS_SPOOFED

Type:Enumeration
Readable:Yes
Writeable:Yes
Default Value:0
Values:
0UNSET
1CENTRAL_ADDRESS_SPOOFED

CONFIG_PENDING

Type:Boolean
Readable:Yes
Writeable:No

DEVICE_IN_BOOTLOADER

Type:Boolean
Readable:Yes
Writeable:No

LOWBAT

Type:Boolean
Readable:Yes
Writeable:No

RSSI_DEVICE

Type:Integer
Readable:Yes
Writeable:No

RSSI_PEER

Type:Integer
Readable:Yes
Writeable:No

STICKY_UNREACH

Type:Boolean
Readable:Yes
Writeable:Yes

UNREACH

Type:Boolean
Readable:Yes
Writeable:No

UPDATE_PENDING

Type:Boolean
Readable:Yes
Writeable:No

Channel 1

Device Configuration Parameters

AES_ACTIVE

Type:Boolean
Default Value:false

METER_CONSTANT_GAS

Type:Float
Unit:m3/Imp.
Minimum Value:0
Maximum Value:65,54
Default Value:0,01

METER_CONSTANT_IR

Type:Integer
Unit:U./kWh
Minimum Value:1
Maximum Value:65536
Default Value:100

METER_CONSTANT_LED

Type:Integer
Unit:Imp./kWh
Minimum Value:1
Maximum Value:65536
Default Value:10000

METER_SENSIBILITY_IR

Type:Integer
Unit:%
Minimum Value:-99
Maximum Value:99
Default Value:0

METER_TYPE

Type:Enumeration
Default Value:3

Variables

BOOT

Type:Boolean
Readable:Yes
Writeable:No
Default Value:false

ENERGY_COUNTER

Type:Float
Unit:Wh
Readable:Yes
Writeable:No
Minimum Value:0
Maximum Value:838860,7

GAS_ENERGY_COUNTER

Type:Float
Unit:m3
Readable:Yes
Writeable:No
Minimum Value:0
Maximum Value:2147483,65

GAS_POWER

Type:Float
Unit:m3
Readable:Yes
Writeable:No
Minimum Value:0
Maximum Value:16777,22

POWER

Type:Float
Unit:W
Readable:Yes
Writeable:No
Minimum Value:0
Maximum Value:167772,15